MPTUTIL(8)		FreeBSD	System Manager's Manual		    MPTUTIL(8)

NAME
     mptutil --	Utility	for managing LSI Fusion-MPT controllers

SYNOPSIS
     mptutil version
     mptutil [-u unit] show adapter
     mptutil [-u unit] show config
     mptutil [-u unit] show drives
     mptutil [-u unit] show events
     mptutil [-u unit] show volumes
     mptutil [-u unit] fail drive
     mptutil [-u unit] online drive
     mptutil [-u unit] offline drive
     mptutil [-u unit] name volume name
     mptutil [-u unit] volume status volume
     mptutil [-u unit] volume cache volume enable|disable
     mptutil [-u unit] clear
     mptutil [-u unit] create type [-q]	[-v] [-s stripe_size]
	     drive[,drive[,...]]
     mptutil [-u unit] delete volume
     mptutil [-u unit] add drive [volume]
     mptutil [-u unit] remove drive

DESCRIPTION
     The mptutil utility can be	used to	display	or modify various parameters
     on	LSI Fusion-MPT controllers.  Each invocation of	mptutil	consists of
     zero or more global options followed by a command.	 Commands may support
     additional	optional or required arguments after the command.

     Currently one global option is supported:

     -u	unit
	     unit specifies the	unit of	the controller to work with.  If no
	     unit is specified,	then unit 0 is used.

     Volumes may be specified in two forms.  First, a volume may be identified
     by	its location as	[xx:]yy	where xx is the	bus ID and yy is the target
     ID.  If the bus ID	is ommitted, the volume	is assumed to be on bus	0.
     Second, on	the volume may be specified by the corresponding daX device,
     such as da0.

     The mpt(4)	controller divides drives up into two categories.  Configured
     drives belong to a	RAID volume either as a	member drive or	as a hot
     spare.  Each configured drive is assigned a unique	device ID such as 0 or
     1 that is show in show config, and	in the first column of show drives.
     Any drive not associated with a RAID volume as either a member or a hot
     spare is a	standalone drive.  Standalone drives are visible to the	oper-
     ating system as SCSI disk devices.	 As a result, drives may be specified
     in	three forms.  First, a configured drive	may be identified by its
     device ID.	 Second, any drive may be identified by	its location as	xx:yy
     where xx is the bus ID and	yy is the target ID for	each drive as dis-
     played in show drives.  Note that unlike volumes, a drive location	always
     requires the bus ID to avoid confusion with device	IDs.  Third, a stand-
     alone drive that is not part of a volume may be identified	by its corre-
     sponding daX device as displayed in show drives.

     The mptutil utility supports several different groups of commands.	 The
     first group of commands provide information about the controller, the
     volumes it	manages, and the drives	it controls.  The second group of com-
     mands are used to manage the physical drives attached to the controller.
     The third group of	commands are used to manage the	logical	volumes	man-
     aged by the controller.  The fourth group of commands are used to manage
     the drive configuration for the controller.

     The informational commands	include:

     version
	     Displays the version of mptutil.

     show adapter
	     Displays information about	the RAID controller such as the	model
	     number.

     show config
	     Displays the volume and drive configuration for the controller.
	     Each volume is listed along with the physical drives that the
	     volume spans.  If any hot spare drives are	configured, then they
	     are listed	as well.

     show drives
	     Lists all of the physical drives attached to the controller.

     show events
	     Display all the entries from the controller's event log.  Due to
	     lack of documentation this	command	isn't very useful currently
	     and just dumps each log entry in hex.

     show volumes
	     Lists all of the logical volumes managed by the controller.

     The physical drive	management commands include:

     fail drive
	     Mark drive	as ``failed requested''.  Note that this state is dif-
	     ferent from the ``failed''	state that is used when	the firmware
	     fails a drive.  Drive must	be a configured	drive.

     online drive
	     Mark drive	as an online drive.  Drive must	be part	a configured
	     drive in either the ``offline'' or	``failed requested'' states.

     offline drive
	     Mark drive	as offline.  Drive must	be a configured, online	drive.

     The logical volume	management commands include:

     name volume name
	     Sets the name of volume to	name.

     volume cache volume enable|disable
	     Enables or	disables the drive write cache for the member drives
	     of	volume.

     volume status volume
	     Display more detailed status about	a single volume	including the
	     current progress of a rebuild operation if	one is being per-
	     formed.

     The configuration commands	include:

     clear   Delete the	entire configuration including all volumes and spares.
	     All drives	will become standalone drives.

     create type [-q] [-v] [-s stripe_size] drive[,drive[,...]]
	     Create a new volume.  The type specifies the type of volume to
	     create.  Currently	supported types	include:

	     raid0   Creates one RAID0 volume spanning the drives listed in
		     the single	drive list.

	     raid1   Creates one RAID1 volume spanning the drives listed in
		     the single	drive list.

	     raid1e  Creates one RAID1E	volume spanning	the drives listed in
		     the single	drive list.

	     Note: Not all volume types	are supported by all controllers.

	     If	the -q flag is specified after type, then a ``quick'' initial-
	     ization of	the volume will	be done.  This is useful when the
	     drives do not contain any existing	data that need to be pre-
	     served.

	     If	the -v flag is specified after type, then more verbose output
	     will be enabled.  Currently this just provides notification as
	     drives are	added to volumes when building the configuration.

	     The -s stripe_size	parameter allows the stripe size of the	array
	     to	be set.	 By default a stripe size of 64K is used.  The list of
	     valid values for a	given type are listed in the output of show
	     adapter.

     delete volume
	     Delete the	volume volume.	Member drives will become standalone
	     drives.

     add drive [volume]
	     Mark drive	as a hot spare.	 Drive must not	be a member of a vol-
	     ume.  If volume is	specified, then	the hot	spare will be dedi-
	     cated to that volume.  Otherwise, drive will be used as a global
	     hot spare backing all volumes for this controller.	 Note that
	     drive must	be as large as the smallest drive in all of the	vol-
	     umes it is	going to back.

     remove drive
	     Remove the	hot spare drive	from service.  It will become a	stand-
	     alone drive.

EXAMPLES
     Mark the drive at bus 0 target 4 as offline:

	   mptutil offline 0:4

     Create a RAID1 array from the two standalone drives da1 and da2:

	   mptutil create raid1	da1,da2

     Mark standalone drive da3 as a global hot spare:

	   mptutil add da3

SEE ALSO
     mpt(4)

BUGS
     The handling of spare drives appears to be	unreliable.  The mpt(4)
     firmware manages spares via spare drive ``pools''.	 There are eight pools
     numbered 0	through	7.  Each spare drive can only be assigned to a single
     pool.  Each volume	can be backed by any combination of zero or more spare
     pools.  The mptutil utility attempts to use the following algorithm for
     managing spares.  Global spares are always	assigned to pool 0, and	all
     volumes are always	backed by pool 0.  For dedicated spares, mptutil
     assigns one of the	remaining 7 pools to each volume and assigns dedicated
     drives to that pool.  In practice however,	it seems that assigning	a
     drive as a	spare does not take effect until the box has been rebooted.
     Also, the firmware	renumbers the spare pool assignments after a reboot
     which undoes the effects of the algorithm above.  Simple cases such as
     assigning global spares seem to work ok (albeit requiring a reboot	to
     take effect) but more ``exotic'' configurations may not work reliably.

     Drive configuration commands result in an excessive flood of messages on
     the console.

HISTORY
     The mptutil utility first appeared	in FreeBSD 8.0.

FreeBSD	11.1			August 16, 2009			  FreeBSD 11.1

NAME | SYNOPSIS | DESCRIPTION | EXAMPLES | SEE ALSO | BUGS | HISTORY